TURBINE FLOWMETER

Principal of operation:-

Exe-Precise Process Equipments are useful for liquids & gases in general industrial application. They provide excellent performance with quality & reliability. Suitable for as hygienic application. The flowing media engages a vanned rotor causing it to rotate at an angular velocity proportional to flow rate. The pick -of coil senses the spinning motion of the rotor inside the pipe & converts it into a pulsating electrical signal. Summation of the pulsating electrical signal is directly related to the total flow. The frequency is linearly proportional to flow rate which is converted to mA signal by electronic circuitry. Flow rate Indicator / Totalizer / Transmitter and Controllers are available in Local/Remote and Panel Mounted Options.

Applications

Fluid : Clear Liquids & Gases Flow Units : M3/H,M3/M,M3/SL/H,L/M,L/S,USG/H,USG/M,USG/S
Viscosity : Up to 20 cp Design Temperature : Up to 110C
Design Pressure : Up to 25 Kg/cm2 Power Supply : 220 VAC/24VDC
Line Size : 15 NB to 200 NB Output :  4- 20 mA+HART
Available Materials : SS304 /SS304L/SS316/SS316L Relay Output : Batcher
Connection : Flanged to ASA/BS/DIN/ Triclover Standard Screwed to BSP/NPT(M/F) Accuracy : +-1% of FSD & +- 0.5% on request
Flow rate Display : 8 Digit LCD Communication port : RS485(Modbus) (Option)
Totalizer Display : 10 Digit LCD Lowest velocity : 0.1 m/s
*Protection : IP66 / Ex-Proof; Optional: IP 68